NT-Ice.com > Manitowoc Ice Thickness Control - 76-2781-3
Manitowoc Ice Thickness Control - 76-2781-3
Manitowoc Ice Thickness Control Probe - 76-2781-3
For use on all B, J, and Q-Model Ice Machines (Except Q-0210)
Installation of single probe ice thickness control:
- The single probe ice thickness control snaps directly onto the original probe mounting bracket
- Connect the single wire to the probe to terminal IC on the control board
- No wire will be attached to terminal ID on the control board
Note:
J-Model control boards that have only terminal IC (no terminal ID on the board), must use the single probe ice thickness control.